Single-Phase Power Metering AFE:AL81XX
· 3.3V power supply: 2.9V to 3.6V. · Reference: 1.210V (typical drift 10ppm/°C). · Typical power dissipation in full operation: 1.3mA (+-10%).(AL8110)/Power dissipation in full operation: 1.7mA (+-10%).(AL8120) · Supporting one current channel for active and reactive energy metering simultaneously(AL8110)/Supporting two current channels for active energy metering and one current channel reactive energy metering simultaneously(AL8120) · Highly metering accurate: Supporting IEC 62053-21:2003, IEC 62053-22:2003 and IEC 62053-23:2003; Less than 0.1% error for active/reactive energy metering over a dynamic range of 5000:1; · 2 independent oversampling ∑/∆ ADCs: one for voltage and one for current.(AL8110) · 3 independent oversampling ∑/∆ ADCs: one for voltage and two for currents(AL8120) · Various measurements: DC components of voltage and current signals; Instantaneous /average current and voltage RMS; Instantaneous /average active/reactive power; Line frequency; Phase · Automatic baud rate adaption UART interface, supporting baud rate: 1200bps~9600bps · No input crystal required. · Current input: Shunt resistor or CT · Operating temperature: -40~+85°C. · Storage temperature: -55~+150°C. · Package: AL8110 8-SOP/AL8120 16-SOP
|
|