AnaLutions, Inc.

Tailored Mixed-Signal and Analog Solutions

Home

IPs

ADC

DAC

Clock Generation

Others

Products

AL 1031

AL 3021

AL 5021

AL 6021

AL 6111A

AL 6111S

AL 70XX

AL 80R1

AL 81XX

Clients & Partners

About

Governance

Brands

Contact

 
Single-Phase Power Metering AFE:AL81XX 


· 3.3V power supply: 2.9V to 3.6V.
· Reference: 1.210V (typical drift 10ppm/°C).
· Typical power dissipation in full operation: 1.3mA (+-10%).(AL8110)/Power dissipation in full operation: 1.7mA (+-10%).(AL8120)
· Supporting one current channel for active and reactive energy metering simultaneously(AL8110)/Supporting two current channels for active energy metering and one current channel reactive energy metering simultaneously(AL8120)
· Highly metering accurate:
  Supporting IEC 62053-21:2003, IEC 62053-22:2003 and IEC 62053-23:2003;
  Less than 0.1% error for active/reactive energy metering over a dynamic range of 5000:1;
· 2 independent oversampling ∑/∆ ADCs: one for voltage and one for current.(AL8110)
· 3 independent oversampling ∑/∆ ADCs: one for voltage and two for currents(AL8120)
· Various measurements:
  DC components of voltage and current signals;
  Instantaneous /average current and voltage RMS;
  Instantaneous /average active/reactive power;
  Line frequency;
  Phase
· Automatic baud rate adaption UART interface, supporting baud rate: 1200bps~9600bps
· No input crystal required.
· Current input: Shunt resistor or CT
· Operating temperature: -40~+85°C.
· Storage temperature: -55~+150°C.
· Package: AL8110 8-SOP/AL8120 16-SOP


© 2018 AnaLutions, Inc.